Universal I/O TTL Input UNIV-TTLIN/IL
- Details
- Category: Universal I/O Modules
- Last Updated on Tuesday, 08 June 2021 11:46
- Hits: 7009
The UNIV-TTLIN/IL Universal I/O module provides two TTL level inputs to the Event Generator. The input terminated can be set by a jumper to either 50 ohm to ground or 240 ohm to +5V. The inputs are 5V tolerant even when powered down.
Input specifications are following:
parameter | value |
connector type | LEMO EPK.00.250.NTN |
input impedance | 50 ohm, 240 ohm or high impedance |
VIH | > 2.3 V |
VIL | < 1.0 V |